12 month warranty Request a Quote Technical Support
US

Product Specifications

Contact Us

Product Description

The Fisher R222H first-stage regulator is designed to reduce the tank pressure for the second-stage regulator in domestic applications. Inlet and outlet gauge taps allow for easy system testing, even in underground tanks. The combination of a high capacity relief valve and large vent provide overpressure protection that exceeds UL standards. When used in conjunction with an R622 or R652, the two-stage system will limit the downstream pressure from the second-stage to 2 psig even in a double failure situation.

Maximum inlet pressure is 250 psig (17.2 bar) with propane flow capacities up to 2,000,000 BTU/hr. Inlet options include 1/2 or 3/4in female NPT or female POL, with outlet connections 1/2 or 3/4in female NPT. The vent is 3/8in NPT screened. Operating temperature range is -20 to 160°F (-29 to 71°C) with a 20-year recommended replacement life. UL listed and CRN certified.

Fisher equipment must be installed, operated and maintained in accordance with Federal, state, and local codes and Fisher instructions. Only personnel trained in the proper procedures, codes, standards and regulations of the LP-gas industry should install and service this equipment.

Fisher

First-Stage LP-Gas Regulator - 2.0M BTU/hr | Fisher R222H

250psi Inlet, 1/2-3/4in
MPN/Series: R222H

Product Specifications

Manufacturer : Fisher

Product Number : R222H

Type : First-Stage LP-Gas Regulator

Maximum Inlet Pressure : 250 psig (17.2 bar)

Propane Flow Capacity : Up to 2,000,000 BTU/hr

Inlet Connection : 1/2 or 3/4in female NPT or female POL

Outlet Connection : 1/2 or 3/4in female NPT

Vent : 3/8in NPT screened

Operating Temperature : -20 to 160°F (-29 to 71°C)

Replacement Life : 20-year recommended

Certifications : UL listed, CRN certified

Documents: Product Manual, Product Specs

Contact Us
Contact Us