12 month warranty Request a Quote Technical Support
US

Product Specifications

Contact Us

Product Description

The E+H Proline Promag H 300 electromagnetic flow meter measures volume flow, temperature, conductivity, mass flow, corrected volume flow, and corrected conductivity. It is designed for hygienic applications with highest requirements in the food and beverage and life sciences industries .

The bidirectional measuring principle is independent of pressure, density, temperature, and viscosity. With no moving parts, the meter is maintenance-free and suffers no pressure loss due to cross-section constriction .

The transmitter offers full access to process and diagnostic information via numerous freely combinable I/Os and fieldbuses, including HART, PROFIBUS, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, and OPC-UA. Up to three analog or digital outputs are available .

The meter features a PFA liner and stainless steel sensor housing (3A, EHEDG approved). Wetted materials are CIP and SIP cleanable. Media temperature range is -4 to 302°F. Standard accuracy is ±0.5% o.r. ± 1 mm/s, with optional ±0.2% o.r. ± 2 mm/s. Optional Heartbeat Technology complies with ISO 9001:2008 Section 7.6a requirements for traceable verification (TÜV-attestation) .

Endress+Hauser

Hygienic Electromagnetic Flow Meter - Food/Beverage, 1/12-6in | E+H Proline Promag H 300

Hygienic Magmeter, 1/12-6in, CIP/SIP, 3A/EHEDG
MPN/Series: Promag H 300

Product Specifications

Manufacturer: Endress+Hauser

Product Number: Proline Promag H 300

Type: Electromagnetic Flow Meter

Nominal Diameter: DN 2 to 150 (1/12 to 6 in)

Flow Range: 0.015 to 2,650 gal/min

Media Temperature Range: -4 to 302°F (-20 to 150°C)

Liner: PFA

Housing: Stainless steel (3A, EHEDG)

Maximum Measured Error: Standard: ±0.5% o.r. ± 1 mm/s; Optional: ±0.2% o.r. ± 2 mm/s

Digital Communication: HART, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

Enclosure Rating: IP66/67, Type 4X standard; IP69 optional

Hygienic Approvals: 3A, EHEDG, FDA-compliant seals, CIP/SIP cleanable

Documents: Product Manual, Product Specs

Contact Us
Contact Us