Product Specifications
Manufacturer:WIKA Alexander Wiegand SE & Co. KG
Product Number:CTI5000
Type:Portable Infrared Calibrator
Temperature Range:50°C to 500°C (122°F to 932°F)
Stability:±0.1°C at 100°C; ±0.2°C at 350°C; ±0.4°C at 500°C
Emissivity:0.95 (fixed)
Target Diameter:57 mm (2.24 in)
Setpoint Resolution:0.1°C
Heating Time:30 minutes from ambient to 500°C
Cooling Time:40 minutes from 500°C to 100°C
Reference Sensor Bore:Located directly behind target surface for contact verification
Power Supply:115 VAC or 230 VAC, 50/60 Hz
Dimensions:Approx. 280 x 160 x 280 mm
Weight:Approx. 5.5 kg (12 lb)
Applications:Testing and calibration of non-contact thermometers, on-site calibration, laboratory reference source
Documents: Product Specs
Product Description
The WIKA CTI5000 is a portable infrared calibrator designed for testing and calibration of non-contact temperature measuring instruments across a range of 50°C to 500°C. Its combination of stability and portability makes it particularly suitable for calibrating handheld infrared thermometers in both laboratory and field environments.
The blackbody target features a 57 mm diameter measuring surface with fixed emissivity of 0.95, accommodating a wide variety of infrared thermometers regardless of lens configuration. Temperature can be set in 0.1°C increments, with stability maintained at ±0.1°C up to 100°C, ±0.2°C up to 350°C, and ±0.4°C at 500°C. Heating time from ambient to 500°C is approximately 30 minutes, with cooling from 500°C to 100°C taking 40 minutes.
A key feature is the reference sensor bore located directly behind the target surface, allowing users to insert a contact reference thermometer for quality monitoring and verification of the blackbody temperature. This enables traceable calibration and ensures measurement confidence.
The CTI5000 is compact and lightweight, designed for easy transport and on-site use. Simple operation and clear controls make it accessible for technicians requiring reliable infrared calibration without complex setup procedures. Typical applications include calibration workshops, quality assurance laboratories, and field service operations requiring portable temperature reference sources.
Applications
- Testing and calibration of non-contact thermometers and infrared pyrometers
- On-site calibration for industrial maintenance and service
- Reference heat source for laboratory calibration of handheld IR thermometers
Features
- Temperature range: 50°C to 500°C (122°F to 932°F)
- Stability: ±0.1°C to ±0.4°C depending on temperature
- 57 mm blackbody target diameter
- Fixed emissivity: 0.95
- Reference sensor bore for contact verification
- 0.1°C setpoint resolution
- Heating time: 30 minutes to 500°C
- Cooling time: 40 minutes from 500°C to 100°C
- Compact and portable design (approx. 5.5 kg)
- Simple operation for field and laboratory use
Resources & Documentation
Portable Infrared Calibrator - 50 to 500°C, 57mm Target | WIKA CTI5000
Product Specifications
Manufacturer:WIKA Alexander Wiegand SE & Co. KG
Product Number:CTI5000
Type:Portable Infrared Calibrator
Temperature Range:50°C to 500°C (122°F to 932°F)
Stability:±0.1°C at 100°C; ±0.2°C at 350°C; ±0.4°C at 500°C
Emissivity:0.95 (fixed)
Target Diameter:57 mm (2.24 in)
Setpoint Resolution:0.1°C
Heating Time:30 minutes from ambient to 500°C
Cooling Time:40 minutes from 500°C to 100°C
Reference Sensor Bore:Located directly behind target surface for contact verification
Power Supply:115 VAC or 230 VAC, 50/60 Hz
Dimensions:Approx. 280 x 160 x 280 mm
Weight:Approx. 5.5 kg (12 lb)
Applications:Testing and calibration of non-contact thermometers, on-site calibration, laboratory reference source
Documents: Product Specs