Product Specifications
Manufacturer:Isotech (Isothermal Technology)
Product Number:976 Gemini R
Type:Portable Blackbody Calibration Source
Temperature Range:30°C to 550°C (optional 700°C model available)
Stability:±0.1°C
Emissivity:>0.995
Cavity Diameter:65 mm
Cavity Depth:160 mm
Uniformity:±1°C maximum variation (100-500°C range)
Display Resolution:0.01°C (to 99.99°C); 0.1°C (100-550°C)
Heating Time:45 minutes to reach 550°C
Power Consumption:1000 Watts typical
Power Supply:100-130V or 208-240V AC, 50/60 Hz
PC Interface:RS232 or RS422 (included)
Software:Cal Notepad included (Windows 10/11 compatible)
Temperature Controller:PID controller with independent indicator
Included Probe:Platinum resistance thermometer
Calibration Certificate:3-point traceable calibration certificate included (UKAS optional)
Fixed Point Compatibility:Accepts gallium (29.7646°C), indium (156.5985°C), tin (231.928°C), zinc (419.527°C) cells
Dimensions (HxWxD):310 x 265 x 200 mm
Weight:10 kg
Optional Accessories:Orifice plates (10-50mm), carrying case, fixed point cells
Product Description
The Isotech 976 Gemini R is a portable blackbody calibration source designed specifically for calibrating non-contact infrared thermometers and radiation pyrometers over the temperature range of 30°C to 550°C. It serves as a primary radiation source, delivering laboratory-grade performance with low uncertainty calibrations.
The Gemini R features a 65 mm diameter cavity with 160 mm depth and emissivity greater than 0.995, ensuring excellent temperature uniformity. The digital PID controller allows precise temperature setting with 0.1°C resolution, while a separate built-in indicator with an included platinum resistance thermometer provides independent verification of radiance temperature. Temperature stability is maintained at ±0.1°C, with maximum variation of ±1°C across the 100-500°C range.
For the highest precision measurements, the Gemini R accepts ITS-90 fixed point cells including gallium (29.7646°C), indium (156.5985°C), tin (231.928°C), and zinc (419.527°C), achieving uncertainties as low as ±0.25°C. Optional orifice plates (10-50mm) allow aperture restriction for different sensor sizes.
The unit comes standard with Cal Notepad software, which automatically logs and displays temperature data from the calibration bath and the unit under test. The software is compatible with Windows 10/11 and enables data export for report generation. RS232 or RS422 communications are included for PC connectivity.
Each Gemini R includes a 3-point traceable calibration certificate for the built-in indicator and supplied probe, with UKAS accreditation available as an option. Heating time to 550°C is approximately 45 minutes, with typical power consumption of 1000W.
Applications include calibration laboratories, infrared thermometer manufacturing, quality control, and research facilities requiring precise non-contact temperature measurement validation.
Applications
- Calibration of infrared thermometers and radiation pyrometers
- NIST-traceable certification of IR sensors
- Quality control in manufacturing environments
- Research and development temperature validation
- Fixed point calibration for ultra-low uncertainty requirements
Features
- Temperature range: 30°C to 550°C
- Stability: ±0.1°C
- Emissivity: >0.995
- Cavity: 65mm diameter x 160mm depth
- Accepts fixed point cells (Ga, In, Sn, Zn) for highest accuracy
- Independent indicator with included PRT probe
- Cal Notepad software included for data logging
- RS232/RS422 communications standard
- 3-point traceable calibration certificate included
- Optional orifice plates for aperture restriction
- Heating time: 45 minutes to 550°C
- Portable design: 10 kg weight
Resources & Documentation
Blackbody Calibration Source - 30-550°C, ±0.1°C Stability | Isotech 976 Gemini R
Product Specifications
Manufacturer:Isotech (Isothermal Technology)
Product Number:976 Gemini R
Type:Portable Blackbody Calibration Source
Temperature Range:30°C to 550°C (optional 700°C model available)
Stability:±0.1°C
Emissivity:>0.995
Cavity Diameter:65 mm
Cavity Depth:160 mm
Uniformity:±1°C maximum variation (100-500°C range)
Display Resolution:0.01°C (to 99.99°C); 0.1°C (100-550°C)
Heating Time:45 minutes to reach 550°C
Power Consumption:1000 Watts typical
Power Supply:100-130V or 208-240V AC, 50/60 Hz
PC Interface:RS232 or RS422 (included)
Software:Cal Notepad included (Windows 10/11 compatible)
Temperature Controller:PID controller with independent indicator
Included Probe:Platinum resistance thermometer
Calibration Certificate:3-point traceable calibration certificate included (UKAS optional)
Fixed Point Compatibility:Accepts gallium (29.7646°C), indium (156.5985°C), tin (231.928°C), zinc (419.527°C) cells
Dimensions (HxWxD):310 x 265 x 200 mm
Weight:10 kg
Optional Accessories:Orifice plates (10-50mm), carrying case, fixed point cells